Date: Wed, 20 Nov 2013 17:11:05 -0800 From: "Segal, Julie" To: "" Cc: Gary S. Varner , "Kenney, Christopher J." , "Hasi, Jasmine" Subject: Re: for today's meeting - follow up A couple points to follow up from today's meeting: 1) John's simulation results suggested that 25um strips might not give much of an advantage over 50um strips in terms of resolution. In addition to having 1/2 the read-out channels, with 50um strip pitch we wouldn't need any fan-out to the bond pads. This would have two benefits: a) the capacitance would drop from 1.5pF-3.0pF depending on location to 0.7pF for all strips (the bond-pad capacitance, mostly) b) smaller die size and no metal routing would improve process yield 2) For the spectrometer: I gave capacitance numbers based on splitting the metal capacitance evenly between the first (smallest) and last (largest) strip, resulting in 2.0pF for the smallest, 3.4pF for the largest. I could move the pads toward the largest strip to split the final capacitance instead, giving 2.7pF each. Or somewhere in between, or we could make it more uneven if we wanted to "favor" the smaller strips. Gary, do you have any feedback on this issue? We can discuss next week. - Julie