Minutes of the BEAST meeting
Thursday April 30th 8:00a.m. JST
Structure:
Rosen showed updated CAD plots of the structure. The details
of the support were discussed. As noted earlier, supporting
SS rods extend from BEAST to an intermediate ring which is
then attached to the CDC endplates.
There are three rings of holes on the inner part of the endplate:
ring 1 of holes has diameter 162 mm
ring 2 of holes has diameter 176 mm
ring 3 of holes has diameter 247 mm
The holes in ring 1 are also known as "Yamada's holes". The
intermediate ring from BEAST currently is attached to the second
ring and covers the holes in ring 1. Rosen noted that this
can be changed easily if necessary.
Rosen's trip to KEK will begin on May 28th. He will devote a week
to BEAST mechanical issues and will meet with Haba and Yamada to
clarify issues such as those discussed above.
Simulation:
Sahu presented updated simulation results including the shielding
effects of moveable masks on the new lattice. The new results are:
Rates incident on BELLE
e+ Brem | 335 kHz |
e- Brem | 36 kHz |
e+ Coul | 84 kHz |
e- Coul | 6 kHz |
The addition of the e- moveable mask substantially reduces the
e- Brem background.
Sahu checked the sensitivity of the simulation to physical cutoffs:
E_cut
0.1 | 0.05 | 0.02 |
e+ Brem | 315 kHz | 335 kHz | 332 kHz |
e- Brem | 40 kHz | 36 kHz | 36 kHz |
Theta_cut
| 1 mrad | 0.5 mrad | 0.1 mrad |
e+ Coul | 75 kHz | 84 kHz | 82 kHz |
e- Coul | 7 kHz | 6 kHz | 6 kHz |
The second values are the nominal ones. The simulation
appears to be in the "plateau" region.
A request to understand better the details of the discrete
sources of e+ Brem was made. "Why are the peaks so sharp ?
How does DECAY TURTLE work ? Can we see typical trajectories
from the discrete sources ?"
The new background files from Sahu's generator
will be sent to Bozek for incorporation into BELLE GEANT.
Pressure bump studies
More coordination with the accelerator division was requested.
If only a small number of pumps can be adjusted, what is the
optimal location for these pumps to diagnose the background ?
A formal proposal for pressure bump studies should be submitted
to the vacuum experts in mid-May.
Proportional Chambers
A PC board protoype for the
readout circuit (there will be a DC measurement and a pulse measurement)
was submitted and will come back next week.
Diodes
Have not submitted PC board design yet.
Cd-109 sources
To be decided after golden week. Are 22 mm diameter sources
acceptable ?
A new meeting time will be investigated and will be announced later.